PRESSURE SWITCHES
The pressure switches are used in nearly all systems where there are fluids under pressure. They automatically control the energy levels by acting on the feeding of the motor-pumps. Pressure switches are calibrated beforehand to the standard opening and closing pressure of the contacts, but they can be calibrated to diverse pressures by means of an adjustment device and the values that can be obtained are indicated for each one product.
AVAILABLE ITEMS:
Item 682.0000 - Luise P2 Pressure Switch
Technical Features
- Range at rising pressure: 0,5 - 9,5
- Differential at minimum setting: 0,5 - 9,3
- Differential at maximun setting: 0,7 - 9,5
- Factory settings: 1,4 - 2,8
RANGE |
Differential |
Differential |
Factory |
0,5 - 9,5 |
0,5 - 9,3 |
0,7 - 9,5 |
1,4 - 2,8 |
P10 is a new electronic switch pressure with a capacity of a very wide pressure regulation, from 0.5 to 9.5 bar, it can work both in Manual mode and in Time mode being able to set the automatic starting time between 0.1 and 24 hours. The use of the pressure gauge is no longer required as the functioning pressure is indicated very clearly, in real time, by a back-lighted LCD display. The dry stop function protects the electro, with an automatic restart every 15 minutes in the first hour and then every hour until 23 hours.
Item 680.0000 - Luise P1 Pressure Switch
Technical Features
- Range at rising pressure: 1,4 - 4,6
- Differential at minimum setting: 1,0 - 2,1
- Differential at maximun setting: 1,2 - 2,3
- Factory settings: 1,4 - 2,8
RANGE | Differential @ min. settings | Differential @ max. settings | Factory |
1,4 - 4,6 | 1,0 - 2,1 | 1,2 - 2,3 | 1,4-2,8 |
Item 682.0000 - Luise P2 Pressure Switch
Technical Features
- Range at rising pressure: 2,8 - 7,0
- Differential at minimum setting: 1,2 - 2,3
- Differential at maximun setting: 1,6 - 2,7
- Factory settings: 5,4 - 7.0
RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
2.8 - 7.0 | 1.2 - 1.3 | 1.6 - 2.7 | 4,4 - 7,0 |
Item 659.0000 - D FSG2 NE
Technical Features
- Range at rising pressure: 1,4 - 4,6
- Differential at minimum setting: 1,0 - 2,1
- Differential at maximum setting: 1,2 - 2,3
- Factory settings: 1,4 - 2,8
RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
1,4-4,6 | 1,0-2,1 | 1,2-2,3 | 1,4 - 2.,8 |
Item 660.0000 - Square D FSG 2 Pressure Switch
Technical Features
- Range at rising pressure: 1,4 - 2,6
- Differential at minimum setting: 1,0 - 2,1
- Differential at maximum setting: 1,2 - 2,3
- Factory settings: 1,4 - 2,8
RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
1.4 - 2,6 | 1.0 - 2.1 | 1,2 - 2,3 | 1,4-2,8 |
Item 662.0000 - Square D FYG 22
Technical Features
- Range at rising pressure: 2.8 - 7.0
- Differential at minimum setting: 1.2 - 2.3
- Differential at maximum setting: 1.6 - 2.7
- Factory settings: 5.4 - 7.0
RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
2,8 - 7,0 | 1,2 - 1,3 | 1.6 - 2.7 | 5.4 - 7.0 |
Item 663.0000 - SQUARE D FYG 32
Technical Features
- Range at rising pressure: 5.5 - 10,5
- Differential at minimum setting: 1.9 - 3.0
- Differential at maximum setting: 2.3 - 3.4
- Factory settings: 8,0 - 10.5
RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
5,6 - 10.5 | 1.9 - 3.0 | 2.3 - 3.4 | 8.0 - 10.5 |
Item 671.0000 - Dry Running Protection Furnas Pressure Switch
Technical Features
- Range at rising pressure: 0.9 - 5.0
- Differential at minimum setting: 0.9 - 1
- Differential at maximum setting: 1.4 - 1.8
- Factory settings: 1.4 - 2.8
1.4 - 1,6RANGE | Differential @ min. settings | Differential @ max. settings | Factory setting |
0,9 - 5,0 | 0,9 - 1 | 1,4 - 1,8 | 1,4 - 2,8 |