Automatic air feeder - SUPERMAXI

Surge tank A B C D
 lt. 4000-6000 526 108 G 1/2 G 3/4


AUTOMATIC AIR FEEDER - SUPERMAXI - Item # 150.4000

For surge tank up to lt. 6000

Download working scheme

Technical features:

Max. working pressure PN: 10 bar at 20 °C
Max. working temperature: 50 °C
Type of fluid: water.

WORKING CONDITIONS:

Average pressure
of the tank
Tank capacity 
in liters
2.5 BARfino a 7000
3.5 BAR3500-5500
4.5 BAR3500-5500
5.5 BAR2750-4500
6.5 BAR2250-4500
7.5 BAR2250-4500